Magnetic Drive Pump MPH

Low-maintenance, no leakage, safe and reliable commonly used magnetic pump, effectively isolates highly corrosive and dangerous chemical solutions, not only keeps operators away from the threat of chemical solutions, but also fulfills their obligation to protect the environment.

Get A Quote

Description

Magnetic Drive Pump for Sale

The magnetic drive pump is one new type of pump that applies the principles of modern magnetism and uses the magnetic drive of permanent magnets to achieve non-touch torque transmission. When the motor drives the outer rotor assembly to rotate, the magnetic field lines pass through the isolation sleeve to drive the inner rotor through the action of the magnetic field. The assembly and the impeller rotate synchronously. Because the medium is enclosed in a stationary isolating sleeve, the purpose of transfering the medium without leakage is achieved, and the shaft seal leakage of the mechanical transmission pump is solved.

chemical magnetic drive pump Video

Features and Benefits Of pvdf magnetic drive pump

Excellent performance and extensive lineup of leading magnetic drive pump designs.Maximum flow range from 150L/min to 1000L/min

to meet a wide spectrum of applications.

Magnet drive designs have become the standard for applications requiring corrosion resistant pups.Our magnet drive pump designs offer

a wide range of capabilities from compact OEM configurations to our large chemical process pump series.This broad range of magnet

drive pump capabilities is unmatched in the industry making us the leader in magnet drive pump technology

  • Leak free, seal-less construction
  • Simple, modular construction for eas of maintenance.
  • Non-metallic chemically inert materials offer excellent resistance to corrosive fluids.

Magnetic drive circulation pump is full-sealed with motor connecting shaft and impeller are separately equipped with magnetic materials. It is unnecessary to fit with traditional shaft seal and complete-ness sealed constitutive water pump. Avoids defects of pollution after corrosion caused by liquid leakage, that still adopts special ceramics as shaft bearing, characterizing strong resistance for abrasion and corrosion. It’s advanced performance and quality is the optimum liquid transport pump on the industrial equipment.

electro magnetic pump high pressure for pcp parameters specification table

Model

Standard size

Max.

Capacity

(L/min)

50Hz/60Hz

Max.

Head

(m)

50Hz/60Hz

Standard outlet

Specific

Weight

Motor

Inlet

(Inch)

Outlet

(Inch)

Capacity

(L/min)

50Hz/60Hz

Head

(m)

50Hz/60Hz

Output

(KW)

50Hz/60Hz

Phase

MDH-400

G 1-1/2”

G 1-1/2”

280

12.5/11.5

150

8.5

<1.3

0.55,2P

1or3

MDH-401

G 1-1/2”

G 1-1/2”

330/320

18/19

200

12/12.5

<1.3

0.75,2P

3

MDH-422

G 2”

G 1-1/2”

400

23/22

200

18.5

<1.3

1.5,2P

3

MDH-423

G 2”

G 1-1/2”

500

24/22.5

300

20.5/19

<1.3

2.2,2P

3

MDH-425

G 2”

G 1-1/2”

600

29/31

400

25.5/26.5

<1.3

3.7,2P

3

magnetic drive pump 380v Main Application:

Self-radiating structure:

Through heat-dispersion holes provided in the fixed portions of the impeller and the magnet capsule, liquid is circulated under pressure between the spindle

and bearing to reduce friction heat transmission and prevent thermal deformation.

Non-contact structure:

The drive magnet and driven magnet are carefully positioned so that their strong magnetic field limits rear thrust contact of the magnet capsule parts,even

during dry running. As a result, heat generation is greatly reduced and liquid circulation is maintained.

Volute casing divided into two sections:

The CSM series is the first resin magnet pump which uses the pump casing divided into he front casing and the rear casing to form a vortex chamber as an ideal

form. Therefore, internal leakage is kept to a minimum and overall hydraulic efficiency is enhanced.

Robust structure:

All stress bearing portions, such as the front and rear casings, are reinforced by means of ribs to improve the pressure resistance and the mechanical strength

of the pump. The bearing is not only fixed by conventional press fit but is also sandwiched between the abutting portion in the depth of magnet capsule and the

rear end of the impeller to improve its reliability under high temperature.

magnetic drive acid pump Note:

Zero escape: Unlike the conventional centrifugal pump, the seal-less design on the magnetic drive pump has a corrosion-resistant rear casing that separates the drive magnet and the magnet and the magnet capsule. This may avoid liquid leakage, pollution or corrosion problems

Corrosion resisting: The pump body is made of raw material from Europe, stronger corrosion-resistant. You can choose CFRPP or PVDF depending on what kind of chemical liquid you send. The pump spindle can be made from ceramic and SIC. The ceramic spindle is generally applied for low corrosion. Ths SIC spindle is excellent for high corrosion liquid.

Maximum Durability: The geometry of impeller and casing are fine tuned by professional hydraulic program to reduce hydraulic loss and increase pump efficiency, Employs extra powerful permanent NdFeB magnet that be outstanding performance and coupling capability.

Easy to Assemble: The parts are standard easy to assembling checking, maintaining, more convenient and saving more time.

The plastic base is lighter and more corrosion- resistant.

Adjustable flange facilitates piping installation.

plastic magnetic drive pump structure drawing

filter pump magnetic rotor with impeller flow diagram :

Strong Factory Strength

CLEY TECH is one professional company to sell the high quality of Magnetic drive pumps, Miniature Diaphragm Pump, Metering Pump and Household Pumps more than 20 years. Our company specialize in the research and development of Frequency conversion constant pressure multistage Pumps, Variable frequency multistage centrifugal Pumps, Miniature dc drive Pumps, Intelligent gas-fluid vacuum Pumps, Horizontal centrifugal Pumps, Vertical frequency conversion multistage Pumps and miniature precision motors.

High Precision Installation for Magnetic Drive Pump

1. The coupling of the self-priming pump must be firm with a nut, and the nut must be tightened to prevent loosening of the nut, otherwise it will easily cause the impeller to move and cause mechanical failure.
2. When the self-priming pump and the motor are directly connected to drive, pay attention to the coaxiality of the pump shaft and the motor output; the accuracy of the pump installation has a greater impact on the stability and service life of the pump, so you must be careful Installation correction.
3. In order to keep enough liquid in the self-priming pump body to achieve better self-priming ability and prevent dry friction of the mechanical seal, the pump inlet must be higher than the centerline of the pump shaft.

4. When installing the self-priming pump, check strictly whether there are stones, iron sand and other sundries in the pump casing and pipeline.
5. Correct the installation clearance and coaxiality of the self-priming pump coupling and the motor-driven coupling. The allowable deviation of the different shaft degrees is 0.1mm. The height difference between the pump shaft and the motor shaft can be adjusted by padding copper or iron on the foot.
6. When installing the self-priming pump, the electrostatic grounding resistance of the pump and pipeline should meet its specified requirements.
7. Check the unit after 3-4 hours of actual operation. If there are no defects, the main reason is that the installation has been completed, and the shaft should be checked during the trial operation.
8. The bearing body of the self-priming pump is equipped with a cooling water joint with a cooling chamber device for use with a rubber tube or plastic tube with an inner hole of 12, and its thread size is M12x1.75.
9. If a one-way valve is installed on the outlet pipe of the self-priming pump and the pump cannot discharge gas smoothly during the self-priming process, an exhaust water pipe and valve should be added to the outlet of the pump.

Our Service

Packing for big chemical magnetic drive pumps

  • Step 1: PVC film packing, which can ensure that the magnetic submersible pump is completely covered, avoiding water and rust.
  • Step 2: Carton box packing, with a fixed template on the outermost layer.
  • Step 3: All of the packing are inspected carefully by QC before delivery.

Pro-Sale Service of Horizontal magnetic pump

  • Free sample testing service: you can send us the CAD file of the sample you want to cut, we will cut it at the factory and send the cutting video to you, or we can mail the sample to you.
  • Personalized customized solutions: In order to meet your needs of cutting quality and efficiency, we can design unique solutions according to your requirements.
  • Inquiries and consulting services for all permanent magnet pump.

After-Sale Service of Magnetic Drive Pump

  • The warranty period is 2 years for the Magnetic Drive Pump .
  • When you need to replace the wearing parts of Magnetic Drive Pump , we will provide them at the agent price.
  • If there are any problems during the warranty period, we will replace the main parts free of charge.
  • The Magnetic Drive Pump software provides free lifetime update service.
  • 24-hour online technical support (phone, email, Teamviewer, Whatsapp, Skype, WeChat, QQ, etc.)
  • We provide English training videos and user manuals for Magnetic Drive Pump installation and operation, etc. We can also provide technical guidance remotely.
  • Free training at the Cley Tech. factory.
  • The engineer can repair the Magnetic Drive Pump overseas.

Delivery for Magnetic Drive Pump

All of the Magnetic Drive Pump can be shipped worldwide. You can choose shipping by sea, by train, by truck, by air or by international express and DHL, FEDEX, UPS, etc. Click the button below to submit your information, we will provide you with professional service. Welcome!